Research Article Open Access

Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology Change

Essesse Songa Auguste1, Wembe Tafo Evariste1, Madinatou Salomon2 and Belinga Aboudou Jean1
  • 1 University of Douala, Cameroon
  • 2 University of Yaoundé , Cameroon

Abstract

Silicon is a preferred material in the design of medical imaging detectors. It enables reliable and inexpensive detectors to be produced. However, the operation of this material is compromised when irradiated with high radiation of more than 5 &times;1014 particles/cm2of high energy neutrons. The defects caused transform the electrical properties. Therefore, this loss of information compromises the reconstruction of important events. This research paper aims to make a scientific contribution to the reduction of this radiation effects. The proposed solution is obtained by changing the silicon material generally used to design the detectors by a carbon nanotube material. The use of carbon nanotube material allows the detector to reduce the effects of radiation and leakage currents. A particular observation was made on the linear attenuation coefficient μ, the radiation length X0 and the width of the forbidden band Eg. Our results show the best characteristics for a carbon nanotube material compared to silicon. For a cross thermal section equal to &sigma;Si = &sigma;c = 2 &times;10-3b ,the carbon linear attenuation coefficient is great her than the silicon (&mu;Si = 9.979 &times;10-5cm-1 <&mu;C = 3.533 &times;10-4cm-1), For a maximum effective cross section of equal diffusion &sigma;C = 1009 &times;10-3b, (&mu;Si = 0.503 &times;10-3 cm-1 <&mu;C = 1.732 &times;10-3 cm-1), for a minimum effective cross section of equal diffusion &sigma;Si = &sigma;C = 10.09 &times;10-3b, &mu;Si = 0.503 &times;10-3 cm-1 <&mu;C = 1.732 &times;10-3 cm-1. X0si = 22.009 g/cm2 and  X0c= 42.969 g/cm2,  Egsi= 1.2e.V and  Egsi= 5.5e.V. From these results, the carbon material has an attenuation coefficient at least three times higher than that of the silicon material.

American Journal of Engineering and Applied Sciences
Volume 14 No. 3, 2021, 364-370

DOI: https://doi.org/10.3844/ajeassp.2021.364.370

Submitted On: 19 May 2021 Published On: 17 July 2021

How to Cite: Auguste, E. S., Evariste, W. T., Salomon, M. & Jean, B. A. (2021). Reduction of Radiation Effects in Biomedical Imaging Detectors by Technology Change. American Journal of Engineering and Applied Sciences, 14(3), 364-370. https://doi.org/10.3844/ajeassp.2021.364.370

  • 3,220 Views
  • 1,220 Downloads
  • 0 Citations

Download

Keywords

  • Silicon
  • Carbon
  • Technology Change
  • Radiation
  • Biomedical Imaging
  • Attenuation Coefficient
  • Material