Graph Representation for Secondary System of Pressurized Water Reactor with Autocatalytic Set Approach
- 1 Universiti Teknologi Malaysia, Malaysia
Abstract
The pace of nuclear reactor development in increasing and this is caused by the high authoritative ordinance of electricity from the end users. Furthermore, maintaining and controlling nuclear reactor operation are high priorities due to safety reasons. The aim of this paper is to describe the secondary system of Pressurized Water Reactor (PWR) system by using graph. Furthermore, fuzzy graph is used in performing a new graph based on its dynamicity. Finally, the results between crisp and fuzzy graph of the system are compared and verified against published data. The fuzzy graph of a secondary system of pressurized water reactor is better than a crisp graph of the system.
DOI: https://doi.org/10.3844/jmssp.2015.107.112
Copyright: © 2015 Azmirul Ashaari, Tahir Ahmad, Mustaffa Shamsuddin, Wan Munirah Wan Mohamad and Nazira Omar. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
- 3,751 Views
- 2,170 Downloads
- 7 Citations
Download
Keywords
- Graph Theory
- Nuclear Power Plant
- Pressurized Water Reactor (PWR)
- Autocatalytic Set
- Fuzzy Graph